TVN-PSU1
Power supply for TVR11(4/8ch), TVR12(4/8ch), TVR15HD (4/8ch), TVN10 (Non-PoE), TVN11 (Non-PoE)
Power supply for TVR11(4/8ch), TVR12(4/8ch), TVR15HD (4/8ch), TVN10 (Non-PoE), TVN11 (Non-PoE)
8-64 zone Integrated English Security Panel 3A PSU in Small Enclosure including ATS1821, EN50131 Grade 3/ PD6662:2010 / BS8243
8 - 128 Zone integrated English security panel 3A PSU in medium enclosure including ATS1821, EN50131 Grade 3/ PD6662:2010 / BS8243
16-256 Zone integrated English security panel 3A PSU in large enclosure including ATS1821, EN50131 Grade 3/ PD6662:2010 / BS8243
Lenel Access Series, Reader Interface Modules to support the functions of OnGuard.
Drawing cabinets
Please provide at least 2 characters to search.
8 - 128 Zone integrated English security panel 3A PSU in medium enclosure including ATS1821, EN50131 Grade 3/ PD6662:2010 / BS8243
8 - 128 Zone integrated English security panel 3A PSU in medium enclosure including ATS1821, EN50131 Grade 3/ PD6662:2010 / BS8243
The Advisor MASTER (ATS Classic) offers a full-blown intrusion alarm system with more than 79 different input types, including support for EN50131 grade 3 Anti Mask detectors using only 1 input. A maximum of 128 zones (inputs) can be configured to operate in 8 independent alarm systems (areas). Zones may be assigned to a specific area (offices, stores, etc.) or common to multiple areas (reception, canteen). Each area may have a dedicated keypad (RAS) or can be controlled from any keypad. Areas support fullset and partset and can be controlled through PIN codes, cards or wireless keyfobs. Alarms can be reported through various communication paths like PSTN, IP, GSM or ISDN using standard protocols like SIA, XSIA or Contact-ID.
The system is EN50131:2009 Grade 3 and PD6662:2010 / BS8243 compliant.
All ATS Classic panels control 16 doors up to 64 doors. Intrusion and access control is fully integrated allowing users to access doors while at the same time being able to control their areas. All panels also feature the exclusive "3 times badging" to arm.
The ATS Classic range is a family of control panels that all share the same features, software, accessories & manuals and only differ in enclosure size, number of zones and number of areas.
The ATS Classic panels communicate with up to 16 keypads and readers (RAS's) & 15 expanders (DGP's) using the RS485 data bus. All remote devices on the bus are continuously polled to ensure correct operation and availability. Different wiring schemes are supported to allow both new installations as well as retro-fit installations. The bus can be extended using additional modules like repeaters, splitters, optical fiber modules or RS485 to Ethernet converters.
ATS Classic panels are capable of reporting alarms and specified events using a variety of formats (SIA, XSIA, CID, voice messaging and more) via different communication paths like IP, GSM, ISDN or PSTN (built-in). The system also supports multiple paths for primary and backup reporting.
The ATS Classic panels offer total flexibility in programming of up to 255 outputs using 24 macro logic equations. Using PLC functionality special output behavior, input behavior or access control restrictions are available.
Remote diagnostics provides features to support diagnoses of vital system characteristics like power levels, input state or current consumption from the main control panel or expanders.
The ATS Classic control panels have the same software across Europe with different country default setting and language support. This allows international customers to streamline their security equipment and promote common security procedures throughout their organization.
System | |
---|---|
Product type | Integrated Access Control |
Panel type | Hybrid |
No. of keypads / readers | 16 |
Data Gathering Panels (DGP) | 15 |
No. of alarm groups | 138 |
Specified cable | WCAT52 WCAT54 |
Inputs | |
---|---|
Max no. of inputs | 128 |
Onboard inputs | 8 |
Inputs plug-in expansion | 32 |
ATS1202 support | 3 |
Outputs | |
---|---|
No. of outputs | 255 |
No. of onboard outputs | 4 + 8 from ATS1821 |
Area | |
---|---|
No. of areas | 8 |
User/Cards | |
---|---|
Max. no. of users | more than 1000 |
Users with name | 200 |
Max. no. of cards | 2000 |
Max. no. of PIN codes | 2000 |
Access control | |
---|---|
Standard doors on control panel | 16 |
Door groups | 128 |
Floor groups | 64 |
Intelligent doors on 4-door DGPs | 48 |
Communication | |
---|---|
Onboard transmission type | PSTN |
Transmission extension | GSM/GPRS/IP |
Databus type | RS485 |
Event log | |
---|---|
Alarm event log | 1000 |
Access event log | 1000 |
Electrical | |
---|---|
Operating voltage | 13.8 VDC supplied by the panel |
Power supply type | 230 VAC |
Power supply value | 230 V 50 Hz/23 VAC 56 VA |
Current consumption | 250 mA |
Mainboard current consumption | 130 mA |
Max aux power current | 1A |
Glass break fuses | 7 |
Physical | |
---|---|
Physical dimensions | 475mm x 370mm x 160mm |
Net weight | 8.6 kg |
Shipping weight | 9.7 kg |
Colour | Beige |
Material | Metal |
Housing | Large Metal |
Environmental | |
---|---|
Vandal proof | No |
Operating temperature | 0 to 50°C |
Relative humidity | 95% non-condensing |
Environment | Indoor |
IP rating | IP30 |
Standards & regulation | |
---|---|
EN50131 Grade | Grade 3 |
Compliancy | CE |
Certification | Certalarm |
Standards | EN50131 Grade 3 |
Note | |
---|---|
Some indicated numbers may include possible expansions required |